Error E317 - Baxi Luna boiler is not working from the charging station

Post cover: Error E317 - Baxi Luna boiler is not working from the charging station
This content has been automatically translated from Ukrainian.
There is a Konner Sohnen KS 5200 PS charging station. The house has grounding. When connecting, the Baxi Luna shows error E317.
IMG_20251208_113123309.jpg
Let's read the instructions:
317 - Incorrect power supply frequency.
Let's read further.
Baxi - wants 50Hz
KS 5200 PS - provides 50Hz
Google finds no information. AI says that the station does not provide pure 50Hz, and the boiler is very sensitive. It recommends installing a stabilizer that will equalize the frequency, sine wave, etc. Such stabilizers are not cheap and take up quite a bit of space.
I have a bit of distrust towards AI. So before spending money - a bit more information search.
I find information that the boiler does not ignite if there is no real neutral. This is not related to error E317. But it is worth taking a look at my electrical panel.
I have a two-pole AVR that switches between City (A) and Charging Station (B). When the city is connected - the station charges (after the AVR).
Here I saw that I had assembled a completely isolated network. When the AVR switches to the station - the neutral and phase from the city are cut off.
So I reassembled the electrical panel a bit. I power the station from the city to the AVR. That is ALWAYS. If there is no power from the city - the neutral is still available.
Also, the KS 5200 PS instructions state that it needs a grounded neutral. The electricians who did my grounding connected the ground to the neutral bus under the meter. So everything is fine here.
Screenshot 2025-12-08 at 11.54.31.png
We test - and the boiler works. So the error E317 that Baxi was showing did not indicate exactly what was needed. And AI does not always suggest what is necessary.

This post doesn't have any additions from the author yet.

[Personal Experience] How I Dealt with the E03 Error on KS 5200PS
17 Dec 12:05

[Personal Experience] How I Dealt with the E03 Error on KS 5200PS

ElectroKit
ElectroKit@ElectroKit
16 Jan 11:23

Smart socket for the refrigerator during outages

ElectroKit
ElectroKit@ElectroKit
20 Jan 18:04

How much does the WHIRLPOOL W7X 82I OX consume? Charts from the smart socket.

ElectroKit
ElectroKit@ElectroKit
23 Jan 10:34

Interval switching of the refrigerator increases consumption

ElectroKit
ElectroKit@ElectroKit
Where to download an older version of VirtualBox?
26 Jan 12:26

Where to download an older version of VirtualBox?

ElectroKit
ElectroKit@ElectroKit
CHP, HPP, SPP and other "energy reductions": decoding and simple explanation without boring details
02 Feb 17:31

CHP, HPP, SPP and other "energy reductions": decoding and simple explanation without boring details

ElectroKit
ElectroKit@ElectroKit